Sandviç Panellerde Ses Yalıtımı

Sound Insulation in Sandwich Panels

Sound insulation of roof and facade cladding is an important factor that determines the acoustic performance of buildings. The desired parameters and calculation methods for sound insulation of sandwich panels are determined during the design phase. When sound waves hit a surface, some of the wave is reflected, some is absorbed, and the rest is transmitted. These ratios vary depending on the shape of the surface, the sound absorption of the material and the frequency of the sound.

Variation of Sound Transmission Loss Depending on Frequency (dB)

Sound transmission loss of sandwich panels varies depending on frequency. The values ​​of sound transmission losses at different frequencies are given below:

Frequency (Hz) 50 mm 60 mm
125 7,3 8,1
160 9,3 22,1
200 11,7 14,2
250 8,5 14,5
315 11,4 13,0
400 12,3 13,9
500 13,3 13,8
630 14,1 14,6
800 14,7 15,3
1000 15,9 16,0
1250 15,3 15,3
1600 11,5 13,0
2000 11,8 18,3
2500 23,4 24,2
3150 29,2 29,2
4000 32,4 32,5
5000 29,8 29,8
6300 32,5 32,5
8000 36,9 36,9

Sound Absorption Coefficient Changes with Frequency (dB)

The sound absorption coefficient indicates how much sound energy a surface absorbs. Below are the sound absorption coefficients at different frequencies:

Frequency (Hz) 50 mm 60 mm
315 0,08 0,14
400 0,11 0,21
500 0,22 0,25
630 0,20 0,25
800 0,05 0,06
1000 0,59 0,69
1250 0,09 0,12
1600 0,11 0,12
2000 0,04 0,22
2500 0,07 0,08
3150 0,18 0,20
4000 0,07 0,11